It seems to be able to both step up and step down the voltage from both sources to do the 5 stage charging.
Ctek d250s solar panel size.
I connected the ctek d250s to the solar panel for 3 days in full sun and it could not charge the battery over 12 4 volts.
Open circuit voltage of solar panel in full sun is 22 volts dc max.
I want to add solar panels but the manual that comes with unit is silent on the question of what solar input it is able to handle so i queried it with ctek sweden and the following reply has come back from them.
Total power rating of the solar panel.
I currently run my ctek d250s connected to two 100ah lead crystal batteries.
I wanted to know what the input limit was on the redarc.
I added a 250w solar panel today connected it to the d250s to charge while i m not driving.
As stated max permitted is 21 22v.
It charges my two 100ah agm batteries for my fridges and lighting via the alternator.
Most panels seems to have an output above 30v.
You can also assist the power you get from your ctek d250 by adding a ctek smartpass to your system.
Ctek 250s dual specs and yeah i don t see any solar specs either.
I assume they are more suited to a house solar system rather than a 4x4 camping setup.
And the 5 stage charging can get its power from a solar panel or the alternator.
If you ve bought a panel with that high a voltage to use with the ctek you re out of luck.
I put a volt meter to solar panel and it puts out 22 volts open circuit.
Just wanted to confirm difference and maybe this justifies the price difference.
The ctek d250 has a built in solar regulator so the panels you use do not need additional regulators.
Standard wiring for ctek d250s dual.
I tried 2 different batteries.
It is a temperature compensated 5 stage charger battery isolator and mppt controller.
Minimum solar panel is 40w and a maximum 500w.
It has been working fine.
3 i got from a previous question i asked that the maximum input on the solar side for the ctek was 25a.
I have a 250w panel which is under the max voltage at open circuit.
I cannot keep the battery charged with the alternator and solar panel.
Service battery can be agm or flooded type as per user manual.
Warning when using with solar panels the panel open circuit voltage must not exceed 23v dc or the ctek unit may be damaged and the warranty voided.
No external regulator is to be fitted on solar panel.
I ve had a ctek d250s in my hilux canopy for a few years.
Alternator is a standard non electronic type.
Do not use with panels connected in series.